News
2021.01.12 Update UL Listed Clean Agent System
We are pleased to announce that Nittan start to launch UL listed Clean Agent Fire Suppression Systems.
We launch 2 systems, HFC-227ea system named with NIT-200 and FK-5-1-12 system named with NIT-1230.
NIT-200, Nittan HFC-227ea system
It works to extinguish a fire by discharging the gas within 10 seconds by depriving heat of fire and interrupting the chemical reaction that leads to combustion. It is suitable for Class A, B and C fires and provides a highly efficient and reliable solution to protecting high value assets, be it data servers, people or equipment.
Features
●Selectable various pressure system, 25 bar (363 psi), 42 bar (609 psi) and 50 bar (725 psi)
●Selectable wide range of cylinder size, from 9L to 369L
●Safe for use in occupied areas
●Existing Halon/CO2 control systems can be adapted for use with HFC-227ea
●Require minimal storage space
●No clean-up required after discharge
●Zero ozone depleting potential
●Minimal business disruption after discharge
NIT-1230, Nittan FK-5-1-12 system
FK-5-1-12 has been the most environmentally friendly fire suppression systems among existing other gaseous fire suppression systems. Upon discharge, the system has capability to extinguish a fire quickly by discharging the gas within 10 seconds, without any damage to irreplaceable sensitive electronics and papers. Discharged gas leaves no residue and is electrically non-conductive. As well as HFC-227ea, FK-5-1-12 is effective for Class A, B and C fire and safe to use in occupied areas.
Features
●Selectable various pressure system, 25 bar (363 psi), 42 bar (609 psi) and 50 bar (725 psi)
●Selectable wide range of cylinder size, from 9L to 369L
●Safe for use in occupied areas
●Space saving: minimal storage space
●No clean-up required after discharge
●Zero ozone depleting potential
●Atmospheric lifetime of five days
●Minimal business disruption after discharge
News List
2023.04.11Introducing the Explosion-proof Smoke Detector FLS-02EC-H2
2022.07.14Launched New Non-Addressable Multi-tone & Strobe
2022.05.23Model Change of Class 2 JP conventional fire alarm control panel
2022.05.23Notice of Office Relocation
2021.05.27Update New JP Conventional Control Unit for 0KB3 Smoke Detector
2021.01.12Update UL Listed Clean Agent System
2021.01.07Update UL Addressable Battery Cabinet
2020.11.30Update New JP Conventional Beam Detector
2020.11.05Update New JP Conventional Control Panel
2020.10.01Announcement of new president and representative director of Nittan Company, Ltd.
2020.09.30Congratulations! – Hanoi FC win Bamboo Airways National Cup 2020
2020.08.31Updated New Dual Band IR Flame Detector
2020.07.30Sponsorships by Nittan
2020.06.29Updated Product Range Guide of JP Fire Alarm System
2020.04.03Updated the manuals of the following products;
2020.03.16Updated Datasheet of UL Fire Alarm Product
2020.03.03Updated Datasheet of JP Fire Alarm Product
2020.02.25Updated Product Range Guide of Fire Extinguishing Systems
2019.12.27Nittan Company Holiday Closing Dates / 28th Dec. to 5th Jan.
2019.09.25New NITTAN Interface Modules Further Expand EVOLUTION Range Capabilities